alcohol, solvent or glass-cleaners since
they can affect the mechanical properties
of the material and break it. If you
appreciate a crack in the cover, stop the
machine and call the authorised technical
service for repairs; there is a risk of cover
breaking.
-In the event the power cable should get
damaged and have to be replaced, the
repair may only be done by a SAMMIC
approved assistance service.
-Before cleaning, repairing or checking the
machine, you must unplug the machine
from the mains.
-The noise level of a machine in operation,
as measured at a height of 1.6m and a
distance of 1 metre, is 75 dB(A).
Background noise: 32 dB(A).
Oil change
The oil level must be checked weekly. It
should not be below 3/4 of the oil
indicator. Complete the level, if necessary.
Oil must be changed after the first 100
working hours. Afterwards, change oil
every 500 working hours approximately or
at least every 6 months, as well as each
time oil is found to be emulsified. The
accumulated working hours are displayed
when the machine is switched on. To
change oil, unscrew the draining plug and
let the used oil drain out. To fill the pump
with oil, follow the instructions given in the
relevant section.
On pumps with outputs from 40m³/h
upwards, replace the oil filter at the same
time. This filter is of the type used in cars,
as per ref: AWS2, thread 3/4.
The exhaust filtre must be changed every 4
oil changes or on detecting either oil leaks
or oil mist at the escape.
On turning on the machine when the pump
has been working for a total of 500 hours,
the indicator will display 50 and will be
flashing for 10 seconds, indicating that oil
must be changed. During this lapse of
time, the machine will not start, even if the
cover is lowered.
Once oil has been changed, reset the pump
working time according to the following
sequence:
-With the cover open, press STOP. The
vacuum pump will start.
-Lower the cover. The machine will start
and perform a normal cycle.
-Once the vacuum process has started,
press the STOP button quickly. At this
moment, the working time has been reset
to 0. Allow the machine to complete the
cycle.
-Switch the machine off and on, to check
that the working hour display shows 0.
CHANGE OF CONFIGURATION AND
TESTING OF FUNCTIONS
There are three possible configurations of
the electronic board, according to the
machine in which it is fitted.
Configuration "0": Continuous duty, self-
standing machines (V-641 and V-821).
The pump remains on as from the time the
main switch is pressed. This configuration
is intended for machines to be installed in
cold rooms and refrigerating chambers.
Because the pump is on continuously, the
machine is kept hot, which guarantees its
proper operation.
Configuration "1": Discontinued duty, self-
standing machines (V-641 and V-821).
The pump is on only during the vacuuming
and sealing stages.
Configuration "2": Discontinued duty,
desktop machines (V-204, V-253, V-410,
V-421 and V-426). The pump is on only
during the vacuuming stage.
In order to change the machine
configuration, follow the procedure
described below:
WARNING!
The electronic board is fed at 230V, so care
must be taken thorughout the machine
configuration changing and testing
process.
1- Take off the control panel by removing
its 6 front fixing screws and then
remove the cover protecting the
electronic circuit.
2- Press the general switch.
3- Locate two lugs near the word "TEST" on
the electronic board and short-circuit
them with a screwdriver or similar
object. At this moment, the test process
starts: the electronic board activates
each output (Motor, Sealing solenoid
valve, etc.) for one (1) second and its
associated LED on the board should
then turn on. Next to each LED, there is
a text identifying the component being
tested.
4- On completion of the test sequence, the
display indicates the machine
configuration. If you press STOP at this
stage, the pump working time counter
will be zero-reset.
5- In order to change the machine
configuration, press the Incrementer or
Decrementer key until the required
configuration value is shown.
6- To exit the test mode and save the new
configuration, switch the machine off. If
you lower the cover before exiting the
test mode, the machine will not start. In
the event that the working time counter
has been reset, you can read the new
value on the display when the machine
is switched on again.
The electronic board has a function testing
feature as an aid to troubleshooting in the
event of a machine failure.
Execute steps 1, 2 and 3 described in the
previous section. If any component fails to
work during the test, proceed as follows:
-Verify that the component is connected
correctly and is energised. If this is OK
and the component still fails, replace it by
a new one.
-If the component is not energised, check
the voltage at the output of the electronic
board when the associated LED is on. If
there is no voltage, change the electronic
board.
8
ENGLISH
Descarregue o manual em português (PDF, 0.75 MB)
(Considere o meio ambiente e apenas imprima este manual se for realmente necessário)

Loading…

Avaliação

Deixe-nos saber o que você pensa sobre a Sammic V-410 T Máquina vácuo, deixando uma classificação do produto. Quer compartilhar suas experiências com este produto ou fazer uma pergunta? Por favor, deixe um comentário na parte inferior da página.
Você está satisfeito com Sammic V-410 T Máquina vácuo?
Sim Não
Seja o primeiro a avaliar este produto
0 votos

Participe da conversa sobre este produto

Aqui você pode compartilhar o que pensa sobre Sammic V-410 T Máquina vácuo. Se você tiver alguma dúvida, primeiro leia atentamente o manual. A solicitação de manual pode ser feita através do nosso formulário de contato.

Mais sobre este manual

Entendemos que é bom ter um manual em papel para o seu Sammic V-410 T Máquina vácuo. Você sempre pode baixar o manual em nosso site e imprimi-lo você mesmo. Se desejar um manual original, recomendamos que entre em contato com Sammic. Eles podem fornecer um manual original. Você está procurando o manual do seu Sammic V-410 T Máquina vácuo em outro idioma? Escolha o seu idioma preferido em nossa página inicial e pesquise o número do modelo para ver se o temos disponível.

Especificações

Marca Sammic
Modelo V-410 T
Categoria Máquinas vácuo
Tipo de arquivo PDF
Tamanho do arquivo 0.75 MB

Todos os manuais para Sammic Máquinas vácuo
Mais manuais de Máquinas vácuo

Manual Sammic V-410 T Máquina vácuo

Produtos relacionados

Categorias relacionadas

×
Download