Manual Vox CHM6A17IX Exaustor

Precisa de um manual para o seu Vox CHM6A17IX Exaustor? Abaixo você pode visualizar e baixar gratuitamente o manual em PDF em português. Este produto tem atualmente 2 perguntas frequentes, 0 comentários e tem 0 votos. Se este não for o manual que você deseja, por favor contacte-nos.

Seu produto está com defeito e o manual não oferece solução? Vá a um Repair Café para obter serviços de reparo gratuitos.

Manual

Loading…

RECOMMENDATIONS AND SUGGESTIONS
2
The instructions for Use apply to several versions of this appliance. Accordingly, you
may find descriptions of individual features that do not apply to your specific appliance.
INSTALLATI ON
The manufacturer will not be held liable for any damages resulting from incorrect or
improper installation.
Check that the mains voltage corresponds to that indicated on the rating plate fixed to
the inside of the hood.
For Class
I appliances, check that the domestic power supply guarantees adequate
earthing.
Connect the extractor to the exhaust flue through a pipe of minimum diameter 120mm.
The route of the flue must be as short as possible.
Do not connect the extractor hood to exhaust ducts carrying combustion flumes
(boilers, fireplaces, etc.).
If the instructions for installation for the gas hob specify a greater distance specified
The minimum distance between the supporting surface for the cooking vessels on the hob and the
lowest part of the range hood is 650 mm.
Regulations concerning the discharge of air have to be fulfilled.
kitchen smells.
Never use the hood
for purposes other than
for which it has been designed.
Children should be supervised to ensure that they do not play with the appliance.
The symbol is packaging indicates that this product may not be treated as household
waste. Instead it shall be handed over to the applicable collection point for the recycling of
electrical and electronic equipment. By ensuring this product is disposed of correctly, you
will help prevent potential negative consequences for the environment and human health,
which could otherwise be caused by inappropriate waste handling of this product. For more
detailed information about recycling of this product, please contact your local city office,
your household waste disposal service or the shop where you purchased the product.
above, this has to be taken into account.
If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in orderto avoid a hazard.
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning
gas or other fuels(notapplicable to appliances that only discharge the air back into the room).
USE
The extractor hood
has been designed exclusively for domestic use to eliminate
Never leave high naked flames under the hood when it is in operation.
Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that
it does not engulf the sides.
Deep
fat
fryers
must be continuously
monitored during use: overheated oil can burst
into
flames.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lackof experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
personresponsible for their safety.
There shall be adequate ventilation of the room when the range hood is used at the
same time as appliances burning gas or otherfuels (not applicable to appliances that
only discharge the air back into the room).
There is a fire risk if cleaning is not carried out in accordance with the instructions.
Do not flame under the range hood.
CAUTION: Accessible parts may become hot when used with cooking appliances”.
MAINTENAN
CE
The cooker hood and its filter should be cleaned regularly according to the instruction.
Switch off or unplug the appliance from the mains supply before carrying out any
maintenance work.
Clean the hood using a damp cloth
and a neutral liquid detergent.
The ap
pliance uses 4 hob elements at most.
Descarregue o manual em português (PDF, 57.94 MB)
(Considere o meio ambiente e apenas imprima este manual se for realmente necessário)

Loading…

Avaliação

Deixe-nos saber o que você pensa sobre a Vox CHM6A17IX Exaustor, deixando uma classificação do produto. Quer compartilhar suas experiências com este produto ou fazer uma pergunta? Por favor, deixe um comentário na parte inferior da página.
Você está satisfeito com Vox CHM6A17IX Exaustor?
Sim Não
Seja o primeiro a avaliar este produto
0 votos

Participe da conversa sobre este produto

Aqui você pode compartilhar o que pensa sobre Vox CHM6A17IX Exaustor. Se você tiver alguma dúvida, primeiro leia atentamente o manual. A solicitação de manual pode ser feita através do nosso formulário de contato.

Mais sobre este manual

Entendemos que é bom ter um manual em papel para o seu Vox CHM6A17IX Exaustor. Você sempre pode baixar o manual em nosso site e imprimi-lo você mesmo. Se desejar um manual original, recomendamos que entre em contato com Vox. Eles podem fornecer um manual original. Você está procurando o manual do seu Vox CHM6A17IX Exaustor em outro idioma? Escolha o seu idioma preferido em nossa página inicial e pesquise o número do modelo para ver se o temos disponível.

Especificações

Marca Vox
Modelo CHM6A17IX
Categoria Exaustores
Tipo de arquivo PDF
Tamanho do arquivo 57.94 MB

Todos os manuais para Vox Exaustores
Mais manuais de Exaustores

Perguntas frequentes sobre Vox CHM6A17IX Exaustor

Nossa equipe de suporte pesquisa informações úteis e respostas a perguntas frequentes sobre produtos. Se você encontrar algum dado incorreto em nossas perguntas frequentes, informe-nos usando nosso formulário de contato.

Qual a distância que deve haver entre o meu exaustor e o meu fogão de mesa? Verificado

Isto pode variar dependendo da marca, mas geralmente um exaustor deve ser posicionado pelo menos 65 centímetros acima de um fogão de mesa a gás e pelo menos 50 centímetros acima de um fogão de mesa elétrico ou de indução. Isto é para melhorar a segurança contra incêndios

Isso foi útil (1232) Consulte Mais informação

Preciso de um exaustor com ou sem motor? Verificado

Os exaustores com motor destinam-se a quando o ar é movido diretamente para o exterior. Um exaustor sem motor é adequado para quando existe um sistema de ventilação central. Nunca conecte um exaustor com motor a um sistema de ventilação central!

Isso foi útil (660) Consulte Mais informação